Free AC tonnage calculator

AC Tonnage Calculator

Enter the room's length and width, the ceiling height, how much sun it gets, how many people usually sit in it, and whether cooking happens there — and get the cooling load in tons, BTU per hour and kW, plus the AC size to buy. On the sample — a 12 x 12 ft bedroom, 10 ft ceiling, normal sun, two people, no kitchen — the room is 144 sq ft, the load is 1.2 ton (14,400 BTU an hour, 4.22 kW), so the answer is a 1.5-ton AC. Everything is worked out in your browser; nothing is sent anywhere.

✓ Free to use ✓ No signup ✓ Browser calculation
1.5-ton AC for a 12 x 12 ft bedroom On the sample: 144 sq ft, 1.2 ton of cooling, 14,400 BTU an hour
1.20 TR · 14,400 BTU/hr · 4.22 kW Room area 144 sq ft (13.38 sq m) · 10 ft ceiling · normal sun
Checked 14 November 2026 calcvind.com, desiutility.com, optimist.in, coolinginsights.com and bajajfinserv.in anchors

This is a planning estimate, not an HVAC design. A planning estimate, not an HVAC design. The actual load depends on insulation, windows, climate and how the room is used — get a dealer or installer assessment for large or unusual rooms.

The size your room needs

10 ft is the standard Indian ceiling. A 12 ft ceiling needs 20% more cooling.

Two people are already in the baseline; each extra person adds 0.1 ton.

RECOMMENDED: 1.5-TON AC

RECOMMENDED: 1.5-TON AC

144 SQ FT · 1.20 TR · 14,400 BTU/HR · 4.22 KW

1.5 ton

1.5 ton recommended AC size

Room area
144 sq ft (13.38 sq m)
Raw cooling load
1.20 TR
Cooling needed
14,400 BTU/hr
In kW
4.22 kW
Recommended size
1.5 ton (18,000 BTU/hr)

A 12 x 12 ft bedroom needs a 1.5-ton AC

The room is 144 sq ft (13.38 sq m). At 1 ton per 120 sq ft the base load is 1.20 TR; the 10 ft ceiling keeps it at x1.00, normal sun at x1.00, 2 people add 0.00 ton and cooking heat adds 0.00 ton — so the load is 1.20 TR (14,400 BTU/hr, 4.22 kW). The smallest standard size at or above that is a 1.5-ton AC.

Buy a 1.5-ton AC — a 1-ton AC would run short by 0.2 ton.

144 sq ft / 120 = 1.20 TR base x 1.00 (10 ft ceiling) x 1.00 (normal sun) + 0.00 ton (people) + 0.00 ton (kitchen) = 1.20 TR.
1.20 TR = 14,400 BTU/hr = 4.22 kW. Rounded up to the nearest standard size: 1.5 ton (18,000 BTU/hr).

A planning estimate, not an HVAC design. The actual load depends on insulation, windows, climate and how the room is used — get a dealer or installer assessment for large or unusual rooms.

LineAmountHow it is worked out
Room area144 sq ft (13.38 sq m)12 ft x 12 ft
Baseline load1.20 TR144 sq ft / 120 sq ft per ton
Ceiling heightx1.0010 ft ceiling (height / 10)
Sun exposurex1.00Normal sun
Extra people+0.00 ton2 people (0 beyond two)
Cooking heat+0.00 tonNo cooking in the room
Raw cooling load1.20 TR14,400 BTU/hr · 4.22 kW
Recommended AC size1.5 ton (18,000 BTU/hr)Smallest standard size at or above the load

Figures as of 14 November 2026. Areas are shown to 2 decimal places, the load to 2 decimal places, BTU an hour to whole numbers. The method is the 1-ton-per-120-sq-ft rule with the ceiling, sun, people and cooking adjustments stated on this page.

Recent calculations

No calculations yet — work one out above.

The sample: a 12 x 12 ft bedroom — the answer is a 1.5-ton AC

Enter the room's length and width — in feet, or in metres and the calculator converts (1 m = 3.28084 ft). The ceiling height is in feet; 10 ft is the standard Indian ceiling. Pick the sun exposure: normal, sunny, west-facing, or top floor — a top-floor or west-facing room needs about 20% more cooling. Count the people usually in the room: the first two are already in the baseline, each extra person adds 0.1 ton. Tick cooking heat if the room is a kitchen or a kitchen-diner: cooking adds 0.5 ton. The sample — a 12 x 12 ft bedroom — is filled in.

FigureAmountNote
Room area 144 sq ft (13.38 sq m) 12 ft x 12 ft.
Baseline load 1.20 TR 144 sq ft / 120 sq ft per ton.
Ceiling height x1.00 10 ft ceiling (height / 10).
Sun exposure x1.00 Normal sun.
Extra people +0.00 ton 2 people (0 beyond two).
Cooking heat +0.00 ton No cooking in the room.
Raw cooling load 1.20 TR 14,400 BTU/hr · 4.22 kW.
Recommended AC size 1.5 ton 18,000 BTU/hr — smallest standard size at or above the load.

What does an AC tonnage calculator do?

It works out how much cooling a room needs, in tons, and then rounds that up to the nearest air conditioner size sold in India — 0.8, 1, 1.5, 2, 2.5 or 3 ton. A ton here is a ton of cooling: 12,000 BTU an hour, or 3.517 kW. The rule behind it is simple — about 1 ton for every 120 sq ft at a 10 ft ceiling — adjusted for a higher ceiling, sun, people and cooking heat. Buy too small and the AC runs all day without cooling the room; buy too big and it cools in short bursts, leaves the air damp, and wastes electricity. This page shows the working for every figure, so the answer is checkable.

From the measurements to the size, in four steps

  1. Measure the room

    Measure the length and width in feet — or in metres, and the calculator converts. A 12 x 12 ft room is 144 sq ft. Measure the ceiling height too; most Indian rooms are 10 ft, but a 12 ft ceiling needs 20% more cooling.

  2. Judge the sun

    Pick normal for a shaded or middle-floor room, sunny for a room that gets strong sun, west-facing for afternoon sun through west windows, or top floor for a room directly under the roof. A top-floor or west-facing room needs about 20% more cooling than the same room on a middle floor.

  3. Count the people and the cooking

    Two people are already in the baseline. Each person beyond two adds 0.1 ton — six people in a 12 x 12 ft room add 0.4 ton. If cooking happens in the room, tick cooking heat: it adds 0.5 ton.

  4. Read the size — and buy that size or the next one up

    The calculator shows the raw load in tons, BTU an hour and kW, then the recommended market size, rounded UP to the nearest standard size. A 1.2-ton load means a 1.5-ton AC; a 1.44-ton load also means a 1.5-ton AC. Never round down: a 1.5-ton load in a 1-ton AC is an AC that never stops running.

How the load and the size are worked out

The method is the one the Indian calculators agree on, with the disagreements stated. Baseline: 1 ton per 120 sq ft at a 10 ft ceiling (calcvind.com, desiutility.com, and bajajfinserv.in's own summary — its printed formula, area divided by 600, is wrong and is not used here; 180 divided by 600 is 0.3, not 1.5). Ceiling: multiply by height divided by 10. Sun: normal x1.00, sunny x1.10, west-facing x1.20, top floor x1.20. People: add 0.1 ton for each person beyond two. Cooking: add 0.5 ton. Then round UP to the nearest standard size — 0.8, 1, 1.5, 2, 2.5 or 3 ton — never down. Optimist.in uses a different baseline (120 BTU per sq ft, i.e. area divided by 100), so its raw loads run higher: 180 sq ft is 1.8 ton there and 1.5 ton here, and it recommends a 2-ton AC where this calculator recommends 1.5 ton. Coolinginsights.com adds flat tons on a divided-by-100 base: its top-floor example is 1.5 + 0.5 + 0.25 = 2.25 ton, so a 2.5-ton unit, where this calculator gives 1.5 ton for the same room. Both differences are stated on this page with the arithmetic shown, so the reader can judge.

Nine rooms, nine answers

Six presets from real rooms, and three worked examples from the calculators India actually uses — each one reproduced exactly by this calculator, except where a method difference is stated.

The sample: a 12 x 12 ft bedroom

The room calcvind.com itself works through: 12 ft by 12 ft, 10 ft ceiling, normal sun, two people, no kitchen. Calcvind.com gives 1.5 ton, 144 sq ft, 1.2 ton of cooling, 14,400 BTU an hour and 4.22 kW — and this calculator gives the same figures exactly.

Room 12 ft x 12 ft (144 sq ft, 13.38 sq m) — load 1.20 TR (14,400 BTU/hr, 4.22 kW) — buy a 1.5-ton AC.

A small bedroom: 10 x 10 ft

Calcvind.com's FAQ says a 10 x 10 room needs a 1 ton AC. The room is 100 sq ft, the load is 0.83 ton, and the smallest size at or above that is a 1-ton AC.

Room 10 ft x 10 ft (100 sq ft, 9.29 sq m) — load 0.83 TR (9,960 BTU/hr, 2.92 kW) — buy a 1-ton AC.

A master bedroom: 12 x 15 ft

180 sq ft, so the load is 1.5 ton and the answer is a 1.5-ton AC — desiutility.com says exactly that. Optimist.in says a 2-ton AC for the same room, because it works at 120 BTU per sq ft (area divided by 100, giving 1.8 ton) instead of area divided by 120. The two methods disagree by one size here; this calculator follows the 120 sq ft rule that calcvind.com, desiutility.com and bajajfinserv.in's own summary use.

Room 12 ft x 15 ft (180 sq ft, 16.72 sq m) — load 1.50 TR (18,000 BTU/hr, 5.28 kW) — buy a 1.5-ton AC.

A living room: 15 x 20 ft, four people

300 sq ft is 2.5 ton before anything else, and four people add 0.2 ton — two people are already in the baseline, the other two add 0.1 ton each. The load is 2.7 ton, so the answer is a 3-ton AC. A 2.5-ton AC would run short by 0.2 ton all day.

Room 15 ft x 20 ft (300 sq ft, 27.87 sq m) — load 2.70 TR (32,400 BTU/hr, 9.50 kW) — buy a 3-ton AC.

A top-floor bedroom: 12 x 12 ft under the roof

The same 12 x 12 ft room on the top floor: the roof adds about 20%, so 1.2 ton becomes 1.44 ton — still a 1.5-ton AC, but with almost no margin. Desiutility.com makes the same point for a 150 sq ft top-floor room in Delhi: it needed 1.5 ton, not 1 ton.

Room 12 ft x 12 ft (144 sq ft, 13.38 sq m) — load 1.44 TR (17,280 BTU/hr, 5.06 kW) — buy a 1.5-ton AC.

A kitchen-diner: 12 x 15 ft, sunny, three people, cooking

180 sq ft is 1.5 ton; sun adds 10% (1.65 ton); a third person adds 0.1 ton; cooking adds 0.5 ton. The load is 2.25 ton, so the answer is a 2.5-ton AC — a full ton above the same room as a plain bedroom. Size a kitchen-diner as a bedroom and the AC will never catch up at dinner time.

Room 12 ft x 15 ft (180 sq ft, 16.72 sq m) — load 2.25 TR (27,000 BTU/hr, 7.91 kW) — buy a 2.5-ton AC.

Desiutility's worked example: 12 x 15 ft, top floor

Desiutility.com works this room step by step: 180 sq ft is 1.5 ton, plus 0.2 ton for the top floor, plus 0.1 ton for west windows — 1.8 ton on its own additions (the page prints 1.9, an extra 0.1 it does not explain), rounded up to a 2-ton AC. This calculator gives 1.8 ton and the same 2-ton AC: the recommendation agrees, and the raw load agrees before desiutility's unexplained 0.1.

Room 12 ft x 15 ft (180 sq ft, 16.72 sq m) — load 1.80 TR (21,600 BTU/hr, 6.33 kW) — buy a 2-ton AC.

Coolinginsights' top-floor example: 150 sq ft, top floor, west sun

Coolinginsights.com gives this room 1.5 ton base, plus 0.5 ton for the top floor, plus 0.25 ton for west sun — 2.25T, so a 2.5-ton unit. This calculator gives 1.5 ton and a 1.5-ton AC for the same room: its base is 1.25 ton (150 divided by 120), times 1.20 for the top floor. The difference is the method — flat tons added to a divided-by-100 base, against a percentage factor on a divided-by-120 base — and it is a full size apart, so it is stated here rather than hidden. If the room is genuinely hot in the afternoon, the larger size is the safer buy.

Room 12.5 ft x 12 ft (150 sq ft, 13.94 sq m) — load 1.50 TR (18,000 BTU/hr, 5.28 kW) — buy a 1.5-ton AC.

Measured in metres: 4 m x 5 m

4 metres is 13.12 ft and 5 metres is 16.40 ft, so the room is 215.17 sq ft (19.99 sq m). The load is 1.79 ton, so the answer is a 2-ton AC. Measure in whichever unit is on your tape; the conversion is 1 m = 3.28084 ft.

Room 13.12 ft x 16.4 ft (215.17 sq ft, 19.99 sq m) — load 1.79 TR (21,480 BTU/hr, 6.30 kW) — buy a 2-ton AC.

AC size chart — room area to tonnage

At standard conditions: 10 ft ceiling, normal sun, two people, no cooking. The size is always rounded UP to the nearest standard Indian split-AC size — never down. Calcvind.com's chart agrees except at the bottom: it lists 0.75 ton up to 90 sq ft, where this chart says 0.8 ton — 0.75 ton is a window-AC size, and Indian splits start at 0.8 ton. Desiutility.com's bands are wider (100–130 sq ft to 1 ton, 130–180 to 1.5 ton, 180–250 to 2 ton), so this chart recommends a larger size for rooms just over 120, 180 and 240 sq ft. Coolinginsights.com agrees at 100–120 sq ft (1 ton) and 150–180 sq ft (1.5 ton), and says 2.5 ton for a large hall of 300–400 sq ft — this chart says 2.5 ton up to 300 sq ft and 3 ton above it, and above 360 sq ft it says two ACs or a larger system instead of a single 2.5-ton unit.

Room areaRaw loadRecommended sizeTypical room
Up to 96 sq ft Up to 0.80 ton 0.8 ton Small bedroom, study or office
97–120 sq ft 0.81–1.00 ton 1.0 ton Small bedroom (10 x 10 to 10 x 12 ft)
121–180 sq ft 1.01–1.50 ton 1.5 ton Standard bedroom (12 x 12 to 12 x 15 ft)
181–240 sq ft 1.51–2.00 ton 2.0 ton Master bedroom or small hall
241–300 sq ft 2.01–2.50 ton 2.5 ton Living room (15 x 20 ft)
301–360 sq ft 2.51–3.00 ton 3.0 ton Large living room or hall
Above 360 sq ft Above 3.00 ton Two ACs or a larger system One 3-ton AC is the largest common split size

Every factor in the load, and how it is worked out

Each line on the sample — a 12 x 12 ft bedroom — with the rule behind it. The ceiling and the sun are the two lines people forget, and they are the two that push a room into the next size.

FactorHow it is worked outTypicalOn the sample
Room area Length x width 100 to 300 sq ft for most rooms 144 sq ft (13.38 sq m)
Baseline load Area / 120 sq ft per ton 1 ton per 120 sq ft at a 10 ft ceiling 1.20 ton
Ceiling height x height / 10 +10% for each foot above 10 ft x1.00 at 10 ft
Sun exposure Normal x1.00, sunny x1.10, west-facing x1.20, top floor x1.20 +20% for a top floor or west-facing room x1.00 (normal sun)
People +0.1 ton for each person beyond two Six people add 0.4 ton +0 ton (2 people)
Cooking heat +0.5 ton when cooking happens in the room +0.5 ton for a kitchen-diner +0 ton (no kitchen)
Round up Smallest standard size at or above the raw load Never round down 1.20 ton -> 1.5-ton AC

The rules behind the answer

Six rules, each one checkable against the sources. Nothing here is a surveyed measurement — every factor is a planning rule, and the page says where the sources disagree.

1 ton per 120 sq ft at a 10 ft ceiling

The baseline every Indian calculator starts from: calcvind.com states it as its quick answer, desiutility.com as 'Base tonnage = Area / 120', and bajajfinserv.in's own summary says a 120 sq ft room generally needs about 1 ton. One ton of cooling is 12,000 BTU an hour (3.517 kW), the ASHRAE definition, and AC ratings are tested at 35°C outdoor ambient temperature under IS 1391 Part 2.

Ceiling height scales the load

Multiply by height divided by 10. A 12 x 12 ft room at 8 ft needs 0.96 ton; the same room at 12 ft needs 1.44 ton — the difference between a 1-ton and a 1.5-ton AC. Bajaj Finserv puts it as roughly 10% more for every foot above 10 ft.

Sun adds about 20% for a top floor or west-facing room

Normal sun multiplies by 1.00, sunny by 1.10, west-facing by 1.20, top floor by 1.20. Calcvind.com states about 20% for a top-floor or west-facing room; optimist.in puts a top floor with no insulation at 15–20% more. Coolinginsights.com instead adds flat tons (0.5 for a top floor, 0.25 for west sun) on a divided-by-100 base, which gives a larger answer — its 150 sq ft top-floor west example is 2.25 ton against 1.5 ton here, and the difference is stated in the worked examples.

Each extra person adds 0.1 ton

Two people are already in the baseline. Each person beyond two adds 0.1 ton — calcvind.com, bajajfinserv.in and desiutility.com all state 0.1 ton per extra person. Optimist.in is more cautious and says 0.1 ton per additional two people; this calculator follows the 0.1-per-person figure the other three use.

Cooking heat adds 0.5 ton

Coolinginsights.com adds 0.5 ton for kitchen use, and desiutility.com lists cooking heat as a 0.5-ton factor. A kitchen-diner sized as a bedroom will be short by half a ton at dinner time — the worked example on this page shows a 12 x 15 ft kitchen-diner needing 2.5 ton where the same room as a bedroom needs 1.5 ton.

Round UP to the nearest standard size — never down

Indian split ACs come in 0.8, 1, 1.5, 2, 2.5 and 3 ton. The recommendation is the smallest of those at or above the raw load: 1.2 ton means a 1.5-ton AC, 1.01 ton means a 1.5-ton AC, 2.7 ton means a 3-ton AC. Above 3.0 ton the calculator says so and suggests two ACs or a larger system rather than naming a size that does not exist as a single split.

Common AC sizing mistakes to avoid

SIZE
Buying by the shop's '1 ton per 100 sq ft' shortcut — A shop that divides by 100 will sell a 2-ton AC for a 180 sq ft room; the 120 sq ft rule gives 1.5 ton. Optimist.in works the same way (1.8 ton for 180 sq ft), and its recommendation is a size higher than calcvind.com's and desiutility.com's. Ask which divisor the seller used before paying for the extra half ton.
SUN
Ignoring the top floor — A 150 sq ft top-floor room needs 1.5 ton, not 1 ton — desiutility.com says so from a Delhi case. The roof heats the room all afternoon, and a middle-floor size on a top floor will run all day without reaching the set temperature.
PEOPLE
Forgetting the people in the room — A living room that usually holds six people needs 0.4 ton more than the same room with two people. Six people in a 12 x 12 ft room push the load from 1.2 ton to 1.6 ton — from a 1.5-ton AC to a 2-ton AC.
KITCHEN
Sizing a kitchen-diner as a bedroom — Cooking adds 0.5 ton. A 12 x 15 ft kitchen-diner needs 2.5 ton on the worked example here; sized as a bedroom it would get a 1.5-ton AC and never catch up at dinner time.
STARS
Trusting '5-star saves 20–25%' as a BEE fact — That figure traces to a 2016 press report of a BEE claim (20–22%), and the same study found 5-star units using more power above 40°C. What is checkable today is the ISEER table: a 5-star split AC must have an ISEER of 5.60 or above (2026–27), and on BEE's own label figures a 1.5-ton 5-star uses about 22% fewer units a year than a 3-star of the same size.

Before you trust the result

  • Are the length and width measured wall to wall — and in the right unit, feet or metres?
  • Is the ceiling height the real one — 10 ft is standard, but a 12 ft ceiling needs 20% more cooling?
  • Is the sun exposure honest — is the room really shaded, or does it face west or sit under the roof?
  • Are the people counted — the first two are already in the baseline, each extra person adds 0.1 ton?
  • Is cooking heat ticked if the room is a kitchen or a kitchen-diner — it adds 0.5 ton?
  • Is the recommendation rounded UP — a 1.2-ton load means a 1.5-ton AC, never a 1-ton AC?
  • Is the room above 360 sq ft — and if so, have you planned for two ACs or a larger system instead of one oversized split?
  • Is the star rating checked on the ISEER table, not on a 'saves 20–25%' slogan?
  • Is this a planning estimate — and will you get a dealer or installer assessment before buying for a large or unusual room?

AC tonnage calculator FAQs

How is AC tonnage calculated?
Tonnage = room area in sq ft / 120, times ceiling height / 10, times a sun factor (normal 1.00, sunny 1.10, west-facing 1.20, top floor 1.20), plus 0.1 ton for each person beyond two, plus 0.5 ton for cooking heat. Then round UP to the nearest standard size — 0.8, 1, 1.5, 2, 2.5 or 3 ton. On the sample — a 12 x 12 ft bedroom, 10 ft ceiling, normal sun, two people, no kitchen — that is 144 / 120 = 1.2 ton, so a 1.5-ton AC.
What size AC do I need for a 12 x 12 room?
A 1.5-ton AC. The room is 144 sq ft, the load is 1.2 ton (14,400 BTU an hour, 4.22 kW), and the smallest standard size at or above 1.2 ton is 1.5 ton. Calcvind.com works the same room and gives the same answer.
Is a 1.5 ton AC enough for 180 sq ft?
Yes, by the 1-ton-per-120-sq-ft rule: 180 / 120 = 1.5 ton exactly, so a 1.5-ton AC. Optimist.in says a 2-ton AC for the same room, because it works at 120 BTU per sq ft (area divided by 100, giving 1.8 ton) instead of area divided by 120. Desiutility.com, calcvind.com and bajajfinserv.in all say 1.5 ton for 180 sq ft. If the room is on the top floor or faces west, the answer becomes 2 ton.
What size AC for a top-floor room?
Add about 20% to the load. A 150 sq ft top-floor room needs 1.5 ton (desiutility.com: it needed 1.5 ton, not 1 ton), and a 12 x 12 ft top-floor bedroom needs 1.44 ton — still a 1.5-ton AC, but with almost no margin. Coolinginsights.com gives a larger answer for the same room (2.25 ton, so a 2.5-ton unit) because it adds flat tons to a divided-by-100 base; this calculator multiplies by 1.20 on a divided-by-120 base. If the room is genuinely hot in the afternoon, the larger size is the safer buy.
How much does ceiling height matter?
A lot. The load scales with height divided by 10: a 12 x 12 ft room at 8 ft needs 0.96 ton (a 1-ton AC), at 10 ft it needs 1.2 ton (a 1.5-ton AC), and at 12 ft it needs 1.44 ton (still a 1.5-ton AC, but with less margin). Bajaj Finserv puts it as roughly 10% more cooling for every foot above 10 ft.
Does the number of people in the room matter?
Yes — 0.1 ton for each person beyond two. Two people are already in the baseline. Six people in a 12 x 12 ft room add 0.4 ton, taking the load from 1.2 ton to 1.6 ton and the answer from a 1.5-ton AC to a 2-ton AC. Optimist.in is more cautious and says 0.1 ton per additional two people; this calculator follows the 0.1-per-person figure that calcvind.com, bajajfinserv.in and desiutility.com use.
What does 1 ton mean in BTU and kW?
1 ton of cooling removes 12,000 BTU of heat an hour, which is 3.517 kW of cooling — the ASHRAE definition, stated by calcvind.com, optimist.in, coolinginsights.com and bajajfinserv.in alike. So a 1.5-ton AC removes 18,000 BTU an hour (5.28 kW of cooling). AC ratings are tested at 35°C outdoor ambient temperature under IS 1391 Part 2. Note that kW of cooling is not the electricity the AC draws: a 1.5-ton 5-star inverter typically draws about 1 to 1.5 kW at full load.
Should I buy a 5-star AC?
A higher star rating uses less electricity for the same cooling. Under BEE's star labelling for room air conditioners, a 5-star split AC must have an ISEER of 5.60 or above (January 2026 to December 2027), against 4.30–4.99 for 3-star. On BEE's own label figures, a 1.5-ton 5-star (ISEER 5.80) uses 681 units a year against 878 units for a 3-star (ISEER 4.50) — about 22% fewer units. Do not trust '5-star saves 20–25%' as a current BEE fact: that figure traces to a 2016 press report of a BEE claim, and BEE's own star table could not be read directly when this page was checked.
Is this a substitute for an HVAC design?
No. This is a planning estimate from a rule of thumb, not a surveyed measurement. The actual load depends on insulation, windows, climate and how the room is used — a glass-walled room or a room in a 45°C city needs more than this calculator says. For a large or unusual room, get a dealer or installer assessment before buying. An oversized AC is not harmless either: it cools in short bursts, leaves the air damp, and wastes electricity.

About the method

About the star rating: BEE's star labelling for room air conditioners rates a split AC by its ISEER — the Indian Seasonal Energy Efficiency Ratio. For January 2026 to December 2027 the bands are 3.50–3.79 for 1 star, 3.80–4.29 for 2 star, 4.30–4.99 for 3 star, 5.00–5.59 for 4 star, and 5.60 and above for 5 star (window ACs run lower, 2.90 to 3.70 and above). Those bands come from the gazette notifications S.O. 2794(E) of 16 July 2024 and S.O. 3984(E) of 28 August 2025, as reported by benchmarksutra.in — BEE's own star table could not be read directly on 14 November 2026, because beestarlabel.com serves a stale homepage with no table and the gazette PDF would not fetch. On the label's own annual-units figures, a 1.5-ton 5-star (ISEER 5.80) uses 681 units a year against 878 units for a 3-star (ISEER 4.50): about 22% fewer units. The often-quoted '5-star saves 20–25%' is not printed here as a BEE fact — it traces to a 2016 press report of a BEE claim of 20–22%, and the same study found 5-star units using more power above 40°C.

The rules and examples on this page were checked against calcvind.com, desiutility.com, optimist.in, coolinginsights.com, bajajfinserv.in and vsctimes.com on 14 November 2026, and every worked example on the page reproduces its source exactly except where a method difference is stated — the optimist.in baseline, the coolinginsights.com flat additions, and the bajajfinserv.in divided-by-600 formula, which is not used. The star-rating bands come from the BEE gazette notifications as reported by benchmarksutra.in; BEE's own star table could not be read directly, and the page says so. The tonnage method is a planning rule, not a surveyed measurement. For related tools, the EMI Calculator works out the monthly cost of buying the AC on EMI, the GST Calculator works out the tax on the purchase, the Percentage Calculator works out any percentage the same way, the SIP Calculator plans the monthly saving for the purchase, and the FD Calculator and PPF Calculator plan the saving itself. The Home Loan EMI Calculator and the Income Tax Calculator cover the bigger money questions, and the CGPA Calculator is the same family of tools. Last updated 14 November 2026.

Last updated 14 November 2026.

Plan around the answer — the size, the cost and the rest of your money

Try different figures or a different room — or run the same check with the related tools for your other plans.

WAM to GPA CalculatorGPA to WAM CalculatorSSC Age CalculatorCGPA to Percentage CalculatorAge CalculatorUPSC Age CalculatorIBPS Age CalculatorRRB Age CalculatorEMI CalculatorSIP CalculatorBMI CalculatorPercentage CalculatorGST CalculatorPPF CalculatorFD CalculatorIncome Tax CalculatorRD CalculatorHome Loan EMI CalculatorGratuity CalculatorHRA CalculatorCompound Interest CalculatorEPF CalculatorNPS CalculatorSSY CalculatorNSC CalculatorSCSS CalculatorPost Office MIS CalculatorKVP CalculatorPersonal Loan EMI CalculatorPost Office Time Deposit CalculatorCar Loan EMI CalculatorAPY CalculatorSWP CalculatorWashing Machine Capacity CalculatorMattress Size FinderLaptop Budget CheckerEvent Planning Budget EstimatorRetirement CalculatorStep-up SIP CalculatorHome Loan Eligibility CalculatorLumpsum CalculatorEducation Loan EMI CalculatorBike Loan EMI CalculatorGold Loan CalculatorCredit Card EMI CalculatorSalary CalculatorSimple Interest CalculatorCAGR CalculatorBMR CalculatorBody Fat CalculatorXIRR CalculatorTDS CalculatorRent vs Buy CalculatorPregnancy Due Date CalculatorOvulation Calculator — Fertile Window & Ovulation Date (India)Discount Calculator — Sale Price, Savings & GST (India)Date Calculator — Days Between Dates, Add Days & Countdown (India)Inflation Calculator — Future Cost, Value Today & CII (India)Stamp Duty Calculator — Property Registration Cost (India)Capital Gains Tax Calculator (India) — LTCG & STCG TaxFuel Cost Calculator (India)Share Average Calculator (India)Advance Tax Calculator (India)Brokerage Calculator (India)Leave Encashment Calculator (India)Rooftop Solar Calculator (India)Home Loan Prepayment Calculator (India)DA Calculator (India)Child Education Calculator (India)Sleep Calculator (India)Home Loan Tax Benefit CalculatorGold Price CalculatorAttendance CalculatorEmergency Fund CalculatorSilver Price CalculatorHouse Construction Cost CalculatorElectricity Bill CalculatorPaint CalculatorTerm Insurance CalculatorHealth Insurance Premium CalculatorTiles CalculatorCar Insurance Premium CalculatorTwo-Wheeler Insurance Premium CalculatorPeriod CalculatorConcrete CalculatorProtein CalculatorBrick Calculator